If a capture fails

When a capture stops for a reason, the application names the failure, says what to do about it, and says where the partial file is. Each of those failures has its own remedy — a full disk, a bad cable, the kernel's usbfs limit and a machine that cannot keep up are four different answers, not one.

This page is the same information, gathered, plus the cases where nothing failed but nothing works either.

The file is not lost

However a capture stopped, the FLAC stream is closed properly on the way out. What had already been written is readable and reports its own length, and the message tells you where it is.

The device is not found

Nothing has failed — there is nothing to fail yet. Work through these in order.

Is it on a USB 3 port? A device that enumerated below SuperSpeed appears in the list marked connected at insufficient speed, and is refused rather than opened and left to fail later. Move it to a USB 3 port, directly on the computer rather than through a hub.

Linux: are the udev rules installed? Without them the device node belongs to root, so enumeration finds the device and opening it fails. This is the single most common cause. See Linux device access, and the Flatpak page for the commands — a Flatpak cannot install host udev rules for you.

Windows: is WinUSB bound? Windows will not let the application talk to the device until WinUSB is bound to it, once per machine, with Zadig. See the MSI page.

Does it say recovery mode, no firmware installed? Then it was found, and it needs programming rather than debugging. Go to If an update fails, which covers a board that has never been programmed as well as one whose update was interrupted.

Is something else using it? Only one application can hold the device open. Close the other one — including another copy of this one.

A board running the original firmware

A Duplicator programmed before this application existed enumerates under a different USB identity, and it is named for what it is rather than reported as an absence. The status bar says Original Duplicator firmware — too old for this application to use, the Capture panel's Status line says the same in a sentence, and Tools ▸ Firmware ▸ Update firmware… says so too.

Nothing is broken. That firmware predates both the register interface this application reads and the update mechanism that would replace it, so there is nothing on the board to receive an update — which is why the Firmware window names the state and offers nothing.

Bringing such a board up to current firmware and gateware means programming both directly, and this application does it: Tools ▸ Firmware ▸ Bring up a new or legacy board…. See Bringing up a new or legacy board, which is the same procedure a newly built board needs.

This machine cannot keep up

Three different messages, one family of causes.

This machine could not write the data as fast as the device produced it, and samples were lost.

The device's sequence numbering broke, which means samples were lost. This capture is not bit-perfect.

This machine did not keep a read request outstanding, so the device had nowhere to put its data and samples were lost.

The device produces 80 MB/s continuously and cannot be asked to slow down, so anything that stalls the host for longer than the buffer queue holds costs samples.

Find out which end is short of capacity before changing anything. The Statistics panel says:

Buffer queue Encoder backlog The bottleneck The remedy
Climbing Climbing The FLAC encoder Lower the compression level in the Capture panel
Climbing Near zero The disk Capture to a faster drive
Both near zero, but a stall still happened Something outside the application Raise the buffer queue in Settings, and close whatever else is competing for the machine

For the third message specifically — did not keep a read request outstanding — the setting to change is USB transfers in Settings, and the thing to look at is whatever else is competing for the CPU.

The device reports this family of problems on its own lights as well, as an alternating pattern across the row — see what the lights on the device say.

The kernel's usbfs limit

The kernel's usbfs memory limit is lower than the buffer queue this capture asked for.

Linux only. Raise the limit, which needs administrator rights:

sudo sh -c 'echo 1000 > /sys/module/usbcore/parameters/usbfs_memory_mb'

That lasts until the machine is restarted. The project's udev rules set it permanently — another reason to install them.

Reducing the buffer queue size in Settings works without administrator rights, and is the right answer on a machine you do not administer.

The file could not be written

The capture file could not be created.

Check that the destination folder exists, that it is writable, and that the volume is not full. Choosing a different Folder in File ▸ Settings… is the quickest way to test this.

On Linux with the Flatpak, a folder outside your home directory and the usual mount points needs an explicit grant — see the Flatpak page.

Writing to the capture file failed.

Check the free space on the destination volume, and that the drive has not been disconnected. If the volume is full, free some space or capture to a different drive.

The connection to the device failed.

Check that the device is plugged in and that no other application is using it. Unplugging it and plugging it back in resets the device's own state.

A USB transfer failed.

Try a different cable, and a port connected directly to the computer rather than through a hub. A capture needs a USB 3 port to carry 80 MB/s at all.

The device stopped sending data.

Check the cable and the device's power, then unplug it and plug it back in.

The test pattern did not arrive intact

The device's test pattern did not arrive intact, so something in the capture path is corrupting data.

This is a fault in the hardware or the cabling rather than in the recording — the ramp is generated in the gateware and is known exactly, so a break in it is data that was corrupted in transit. Check the cable and the port, then repeat the test capture. See Test mode.

A fault in the application

The capture failed because of a fault in this application.

Or any failure the application cannot name. Please report it, with the log — start with --debug --log-file ddd.log (command line) to record the full diagnostics into a file, reproduce the fault, then attach that file to the report along with the build commit from Help ▸ About. Copying the Log panel's contents works too, and the file is easier to attach and holds the whole run.

Submitting a bug report says what else is useful.

What the lights on the device say

The FPGA board has a row of eight small lights, and the Duplicator uses them to report what it is doing. They are useful here because they come from the device rather than from this application, so they still answer when the two are not talking to each other at all.

What you see What it means
The two at the ends of the row Connected and idle. This is the normal resting state
All eight lit A capture is running
Alternating, four lit The device's own buffer is overflowing — see below
The middle two A firmware or gateware update is in progress. Leave the device alone
Nothing lit The FPGA has no gateware in it. See Updating your Duplicator
One light, steady, at one end The FPGA is running but the two boards on the device are not talking to each other
One light, blinking every few seconds The FPGA is failing to start and retrying. The device needs its gateware reinstalled

The alternating pattern is the one to know. It means the device filled its internal buffer because this machine was not taking data quickly enough — the same cause as this machine cannot keep up above, and the same remedies apply. Seeing it while a capture runs tells you the bottleneck is between the device and this machine, and not something in the device itself.

The lights show trouble that is happening, not trouble that happened. A brief overflow can come and go faster than the device updates the row, so a capture can lose samples without the pattern ever appearing. Do not read a clean row as proof that a capture was clean — the capture's own result and the Statistics panel are the record, and the lights are the thing you can see from across the room while it is still running.

Warnings that are not failures

Running out of space. The destination volume has less capture time left than the threshold in the Capture panel. Raised once per capture rather than repeatedly, and it does not stop anything — the estimate is an estimate, and stopping a capture on a prediction would sometimes be wrong in the direction that costs a session.

The device did not report which firmware build it is running. On Linux this nearly always means the udev rules are not installed, so the device cannot be opened to be asked — the next thing you try will fail on the same cause. Otherwise it means firmware older than the version stamp itself. Either way it does not block a capture, and the capture's metadata simply records no firmware commit.

There is deliberately no warning for the application's commit differing from the device's. The application is released separately from the firmware and gateware, so those differing is the ordinary state of a fully up-to-date Duplicator. What is worth comparing is the device's two halves against each other, which Tools ▸ Firmware ▸ Update firmware… shows.

Throughput noticeably above 40.00 Msps. Not an error message, but worth knowing: the device is clocked by a 40 MHz converter and physically cannot exceed it. A higher figure means the samples are not coming from the ADC — an unprogrammed FPGA, or gateware that is not the sampler.